超低排放改造后,某电厂1000MW机组动叶可调轴流式引风机频繁发生失速现象,从风机本体、设计参数、管网匹配性等方面入手,分析风机抢风失速原因,并提出了超低排放形势下引风机失速预防措施。

关键词:

Abstract:

After the ultralow emission transformation, there is frequent stalling on adjustable axial flow induced draft fan of a 1000MW unit. According to the body, design parameters and pipe network matching of the fan, the cause of fan stalling is analyzed and the prevention for the stalling of the induced draft fan after ultralow emission transformation are proposed.