华电技术 ›› 2020, Vol. 42 ›› Issue (4): 23-30.

• 储能技术 • 上一篇    下一篇

基于城市功能区划分的分布式相变蓄热站热经济性分析

  

  1.  
    1.天津大学中低温热能高效利用教育部重点实验室,天津 300350;2.中国电力科学研究院有限公司,北京 100192
  • 出版日期:2020-04-25 发布日期:2020-05-15

Thermal economy analysis of distributed phase change heat storage stations based on urban functional zoning

  1. 1.Key Laboratory of Efficient Utilization of Low and Medium Grade Energy,Tianjin University,Tianjin 300350, China;2.China Electric Power Research Institute Company Limited,Beijing 100192,China
  • Online:2020-04-25 Published:2020-05-15

摘要: 中国“三北”地区供暖季“以热定电”的运行方式是造成弃风的重要原因之一,采用蓄热式电锅炉供暖是提高风电消纳率的一种有效方式。将分布式蓄热和相变蓄热相结合,可以充分发挥匹配灵活、蓄热效率高和反应快速等优势。以分布式相变蓄热站的年收益为优化目标,在考虑蓄热约束、供热约束和联合供热约束的条件下,对基于城市功能区划分的分布式相变蓄热站进行了经济性分析。结果表明:区域的热负荷特性对蓄热站供暖期的年收益有显著影响;依据边际效益规律,当商务办公区选取蓄热站容量为 13 200 kW∙h、蓄热功率为 10 800 kW,居民住宅区选取蓄热站容量为11 200 kW∙h、蓄热功率为9 000 kW时蓄热站年收益达到最大值;在选定的容量和蓄热功率下,当商务办公区、居民住宅区的电价分别为0.218,0.221 元(/ kW∙h)时,分布式相变蓄热站可达到收支的平衡。

关键词: 分布式相变蓄热站, 城市功能区, 分布式蓄热, 相变蓄热, 容量优化, 边际效益, 经济性, 可再生能源, 弃风

Abstract: The operation mode of“ Setting Electricity by Heat”taken by the Three-North Region in China during heating seasons is one of the important causes for the wind power abandoning. The utilization rate of wind power can be improved by taking heat storage electric boilers.Combining distributed heat storage and phase change heat storage technologies can give full play to their advantages of flexible matching,high heat storage efficiency and fast response.To increase the annual return of distributed phase change heat storage stations,the economy analysis of distributed phase change heat storage stations based on urban functional zoning is made,while considering the heat storage constraint,heating constraint and combined heating constraint.The analyzing results show that the annual returns of heat storage stations are affected by the characteristics of the regional heat load. According to the law of marginal benefits,the annual return of a heat storage station in commercial area will be maximized with 13 200 kW·h capacity and 10 800 kW heating power,and that in a residential area will peak with 11 200 kW·h capacity and 9 000 kW heating power. With the selected capacity and heating power,the station can reach the break-even point with the electricity price of 0.218 Yuan/(kW·h)in the commercial area and 0.221 Yuan/(kW·h)in the residential area respectively

Key words: distributed phase change heat storage station, urban functional area, distributed heat storage, phase change heat storage, capacity optimization, marginal benefit, economic, renewable energy, wind power abandoning