华电技术 ›› 2009, Vol. 31 ›› Issue (11): 12-14.

• 专题综述 • 上一篇    下一篇

连通管式汽包双色云母水位计偏差分析

刘俊国   

  1. 华电能源股份有限公司牡丹江第二发电厂,黑龙江牡丹江 157015
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2009-11-25 发布日期:2009-11-25

Deviation analysis of connected tube type twocolor mica water gauge for steam drum

LIU Junguo   

  1. Mudanjiang Second Power Plant, Huadian Energy Source Corporation Limited, Mudanjiang 157015, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2009-11-25 Published:2009-11-25

摘要: 对华电能源股份有限公司牡丹江第二发电厂#6机组连通管式汽包双色云母水位计产生偏差的原因进行了分析,针对影响水位计显示值的因素提出了水位测量系统的改造措施。

关键词: 汽包, 水位计, 偏差, 改造

Abstract: The reasons, which caused the deviation of the connected tube type two color mica water gauge of #6 unit steam drum in Mudanjiang Second Power Plant of Huadian Energy Source Corporation Limited, were analyzed. Aiming at the factors influencing the indicated value of the water gauge, the water level measurement system reformation measures were put forward.

Key words: steam drum, water level indicator, deviation, reformation