摘要: 对电除尘器的实际能耗和理论能耗进行了计算分析,得出了电除尘器运行能耗分为有效能耗、无效能耗、反效能耗的结论。开发了脉冲节能供电技术,大幅度降低了无效和反效能耗,提高了电能利用效率,实现了电除尘器的大幅度节能运行。并在工程实践中进行了广泛的应用验证。

关键词: 电除尘器, 节能提效, 供电控制, 功率消耗, 反电晕

Abstract: The actual and theoretical power consumption of ESP was calculated and analyzed. The result shows that the operational power consumption of ESP can be classified into effective power consumption, non-effective power consumption and adversely effective power consumption. The pulsed energy-saving and power supply technology was developed to reduce non-effective and adversely effective power consumption greatly, improve power utilization efficiency and realize the energy-saving operation of ESP. This technology was widely verified in many industrial applications.