华电技术 ›› 2010, Vol. 32 ›› Issue (11): 30-31.

• 技术交流 • 上一篇    下一篇

2种对轮找中心方法结果偏差较大的原因分析

王辉,刘宁一   

  1. 大唐广东潮州发电有限责任公司,广东潮州515723
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2010-11-25

Analysis on reasons of larger deviation between the results of two centring methods for paired wheels

WANG Hui, LIU Ningyi   

  1. Datang Guangdong Chaozhou Power Generation Corporation Limited, Chaozhou 515723, China
  • Received:1900-01-01 Revised:1900-01-01 Published:2010-11-25

摘要: 对某厂低发对轮找中心时2家单位2种找中方心法所存在的问题进行了对比分析,指出了找中心工作应注意的事项,供其他电建及检修单位在对轮找中心时借鉴和参考。

关键词: 对轮, 找中心, 结果偏差

Abstract: In centring for lowpressure cylindergenerator paired wheels of a power plant, the problems existed in two centring methods used by two companies were compared and analyzed. The matters needing attention in centring were pointed out, which can be used as reference for other electric power construction enterprises or overhaul service enterprises in centring.