300MW塔式锅炉灭火原因分析及调整策略

姚中栋   

  1. 姚孟发电有限责任公司,河南平顶山467031
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2012-01-25 发布日期:2012-01-25

Analysis and adjustment strategy of the flameout of 300MW tower type boiler

YAO Zhongdong   

  1. Yaomeng Power Generation Company Limited, Pingdingshan 467031, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2012-01-25 Published:2012-01-25

摘要: 对姚孟发电有限责任公司300MW机组塔式锅炉灭火原因进行了分析,通过冷态动力场试验和有针对性的燃烧调整试验,找出了问题的症结所在,根据电厂的实际情况,提出了合理的运行调整方案及预防措施。实践应用结果表明,锅炉燃烧工况明显改善,未再出现过灭火故障。

关键词: 塔式锅炉, 灭火, 冷态动力场, 燃烧稳定性

Abstract: The reason of flameout of the 300MW tower type boiler in Yaomeng Power Generation Company Limited was analyzed. Based on the coldstate kinetic field experiment and targeted combustion adjustment experiment, the origin of the problem was found. According to the actual situation of the power plant, a rational operation adjustment scheme and preventive measures were put forward. The practical result shows that the boiler combustion condition was improved obviously, and the flameout fault does not occur again.

Key words: tower type boiler, flameout, cold-state kinetic field, stability of combustion