摘要:

摘 要: 以某公司 670 MW 超临界燃煤发电机组为例, 分析了汽轮机气动疏水门故障率高的原因, 给出 了针对性的故障
处理方法, 并提出了预防措施, 实施后故障由每次机组启 停平均发生 16 次降低到 2. 5 次, 取得了良好的效果

关键词: 关键词: 超临界机组, 汽轮机, 气动疏水门, 电磁阀, 故障率, 分析及处理

Abstract:

Abstract:Taking the 670 MW supercritical coalfired unit of a company as example, the reason of high fault rate of steam turbine pneumatic drain valve was analyzed.The targeted fault treatment method was given, and preventive measures were proposed. Originally, the faults occurred 16 times in unit startstopduration in average.After the treatment measures were implemented, the faults occurred 2. 5 times in unit startstop durationin average. The treatment result is favorable.

Key words:

font-family: E-HZ-PK74810c, color: black">Keywordsfont-family: SSJ-PK74820000002, color: black">: font-family: E-BZ-PK748e5, color: black">supercritical unitfont-family: SSJ-PK74820000002, color: black">, font-family: E-BZ-PK748e5, color: black">steam turbinefont-family: SSJ-PK74820000002, color: black">, font-family: E-BZ-PK748e5, color: black">pneumatic drain valvefont-family: SSJ-PK74820000002, color: black">, font-family: E-BZ-PK748e5, color: black">electromagnetic valvefont-family: SSJ-PK74820000002, color: black">, font-family: E-BZ-PK748e5, color: black">fault rate