摘要: 阀控式密封铅酸蓄电池对充电电流、电压、时间、温度均有严格的要求。介绍了免维蓄电池的免维护、密封、温度、充电等特性,分析了福建华安水力发电厂直流系统运行方式的不足,提出了免维护蓄电池的更换和充电方式的技术改进方案,进行了成套微机充电装置的改造。改造的成套GZDW型直流系统微机充电装置投运后,系统运行稳定。

关键词: 免维护蓄电池, 恒压限流, 微机控制, GZDW成套直流电源装置

Abstract: The valve control type lead-acid sealing battery has strict request to charging current, the voltage, the time and the temperature. The characters of maintenance-free accumulator were introduced, such as maintenance, seal, temperature and charge. The disadvantage of direct current operation way in the Hua’an hydropower station was pointed, and the improvement method on the replacement and charge way technique was suggested, while the complete set microcomputer charging set transformation was transformed. The system was stable after the improvement.

Key words: maintenance-free accumulator, constant-voltage &, current-limiting, microcomputer control, GZDW DC power set