华电技术 ›› 2008, Vol. 30 ›› Issue (6): 13-17.

• 专题综述 • 上一篇    下一篇

降低300MWCFB锅炉机组厂用电的探讨

董志乾1,徐巍洁2,郝如平2,康学胜2   

  1. 1.云南大唐国际红河发电有限责任公司,云南 开远 661600; 2.内蒙古京海煤矸石发电有限责任公司,内蒙古 乌海 016000
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2008-06-25

Approach on Reduction of House Power Consumption in 300 MW CFB Boiler Unit

DONG Zhi-qian1, XU Wei-jie2, HAO Ru-ping2, KANG Xue-sheng2   

  1. 1.Yunnan Datang International Honghe Power Generation Co., Ltd., Kaiyuan 661600, China; 2. Inner Mongolia Jinghai Gangue Power Generation Co., Ltd., Wuhai 016000, China
  • Received:1900-01-01 Revised:1900-01-01 Published:2008-06-25

摘要: 分析了300MW CFB机组降低厂用电的必要性,分别从管理、技术改造、运行方式调整的角度介绍了降低300MW CFB机组厂用电的方法,解决了300MW CFB机组厂用电偏高的技术难题,有利于CFB锅炉大型化和在我国的超常规发展。

关键词: CFB机组, 厂用电, 技术措施

Abstract: The necessity of reducing the plant power consumption of 300MW CFB unit was analyzed. Some methods for reducing the house power consumption were introduced from aspects of management, technical reformation and operation mode optimization respectively. The technical difficult problems of the higher auxiliary power consumption rate in 300MW CFB unit were solved, and this is advantageous to the upsizing of CFB boiler capacity and its development in our country.

Key words: CFB unit, house power consumption, technique measurement