高压加热器疏水管道振动原因分析

赖汉贤   

  1. 广东粤泷发电有限责任公司,广东罗定 527217
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2009-05-25 发布日期:2009-05-25

Reason analysis of drain pipe vibration of high pressure heater

LAI Hanxian   

  1. Guangdong Yuelong Power Generation Corporation Limited, Luoding 527217, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2009-05-25 Published:2009-05-25

摘要: 引起设备振动的原因很多,根据#5高压加热器疏水管道振动原因的分析结果,逐项进行了排查和处理,最终找到了引起管道振动的主要原因。采取了有效措施,使高压加热器疏水管道振动的问题得到了明显改善。

关键词: 高压加热器疏水管道, 振动, 原因分析, 排查, 措施

Abstract: There are many reasons which can cause equipment vibration. According to the reason analysis of drain pipe vibration of high pressure heater No.5, the possible reasons were checked and processed one by one, and the main reason causing pipe vibration was found finally. The effective measures were adopted, and the vibration of drain pipe of high pressure heater was weakened obviously.