华电技术 ›› 2010, Vol. 32 ›› Issue (1): 1-3.

• 专题综述 •    下一篇

双膜法在邯钢新区电厂脱盐水站的应用

李宏秀, 李庆柱   

  1. 中国华电工程(集团)有限公司,北京 100035
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2010-01-25

Application of double-membrane method in desalted water station of the Power Plant in Hansteel′s New Developing Area

LI Hongxiu, LI Qingzhu   

  1. China Huadian Engineering Corporation Limited, Beijing 100035, China
  • Received:1900-01-01 Revised:1900-01-01 Published:2010-01-25

摘要: 介绍了邯钢新区电厂脱盐水站的水源、水质条件,在此基础上,分析了水源、水质的各项技术指标。详细论述了双膜法水处理工艺并根据其特点论证了该水处理工艺在邯钢新区电厂脱盐水站应用的可行性。实践结果表明, 该水处理工艺满足了脱盐水站供水水质的要求,其应用取得了良好的效果。

关键词: 脱盐水站, 超滤, 反渗透, 混床, 出水水质

Abstract: The water source and the water quality condition of the desalted water station of the Power Plant in Hansteel′s New Developing Area were introduced. Based on this, the technical indicators of water source and water quality were analyzed. The doublemembrane method water treatment process was discoursed in detail. And, according to its characteristics, the feasibility of application of this water treatment process in the desalted water station of the Power Plant in Hansteel′s New Developing Area was demonstrated. The practice result shows that the water treatment process satisfied the requirement of supply water quality of desalted water station, and excellent application effect was obtained. 

Key words: desalted water station, hyper filtration, reverse osmosis, mixed bed, output water quality