华电技术 ›› 2010, Vol. 32 ›› Issue (4): 54-55.

• 技术交流 • 上一篇    下一篇

电位法检测水内冷发电机定子线棒端部手包绝缘性能

黄中东   

  1. 湖南大唐耒阳发电厂,湖南耒阳421800
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2010-04-25

Insulation performance detection of manualwrapped insulator in terminal of stator bar of internal water cooling generator using potential method

HUANG Zhongdong   

  1. Hunan Datang Leiyang Power Plant, Leiyang 421800, China
  • Received:1900-01-01 Revised:1900-01-01 Published:2010-04-25

摘要: 介绍了汽轮发电机定子端部电位外移试验的测试原理、测试方法及注意事项。湖南大唐耒阳发电厂对2台200MW水内冷发电机进行了该项试验,检测出了发电机端部绝缘存在的许多隐患并采取了相应的处理措施,保证了机组安全、稳定运行。

关键词: 汽轮发电机, 电位外移, 端部绝缘, 手包绝缘

Abstract: The measuring fundamentals of the shifting potential test for the stator bar terminal of the turbogenerator was introduced, the measuring method and matters needing attention were introduced too. The tests have been done for two 200MW water internal cooling generators. Many hidden dangers existed in the terminal insulation of the generators were found, and relevant measures were adopted; the safety and stable operation of the units were ensured.

Key words: turbo-generator, shifting potential, terminal insulation, manual-wrapped insulator