华电技术 ›› 2010, Vol. 32 ›› Issue (7): 64-66.

• 技术交流 • 上一篇    下一篇

灵式滚筒冷渣器冷却水系统的分析与改进

周波,叶辉   

  1. 湖南省火电建设公司热机公司,湖南株洲412000
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2010-07-25 发布日期:2010-07-25

Analysis and reformation of cooling water system of Songling cylindrical slag cooler

ZHOU Bo,YE Hu   

  1. Thermal Machine Branch of Hunan Province Thermal Power Construction Company, Zhuzhou 412000, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2010-07-25 Published:2010-07-25

摘要: 分析了广东韶关坪石电厂(B厂)三期扩建工程2×300MW机组循环流化床冷渣器冷却水系统初始安装中存在的问题,针对运行中出现的问题进行了2次技术改造,对改造经验进行了总结。

关键词: 冷渣器, 循环流化床锅炉, 冷却水系统

Abstract: In the 2×300MW unit of the Guangdong Shaoguan Pingshi Power Plant (Plant B) extension project phase III, the problems existed in the initial installation of the cooling water system of the slag cooler for the circulating fluidized bed boiler were analyzed. Aiming at the problems occurred in operation, the cooling water system had been reformed for two times. The experiences of the reformation were summarized in this paper. 

Key words: slag cooler, circulating fluidized bed boiler, cooling water system