华电技术 ›› 2011, Vol. 33 ›› Issue (2): 24-26.

• 技术交流 • 上一篇    下一篇

高压加热器正常疏水调门开度大的原因分析及预防措施

毕于恒,吕鹏飞,倪国栋   

  1. 安徽华电宿州发电有限公司,安徽宿州234101
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2011-02-25 发布日期:2011-02-25

Reasons analysis and preventive measures on larger opening of normal drainage regulating valve of highpressure heater

BI Yuheng, L Pengfei, NI Guodong   

  1. Anhui Huadian Suzhou Power Generation Corporation Limited, Suzhou 234101, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2011-02-25 Published:2011-02-25

摘要: 针对某电厂600MW超临界机组 #1高压加热器正常疏水调门开度大的原因进行了分析,提出了解决方法及预防措施,可为其他电厂高压加热器的运行提供借鉴和参考。

关键词: 高压加热器, 疏水, 调节门, 堵塞, 防范措施

Abstract: The reasons of larger opening of normal drainage regulating valve of highpressure heater No.1 in 600MW supercritical unit in a power plant were analyzed; and the solving methods and the preventive measures were put forward, which can be used as reference for the highpressure heater operation of other power plants. 

Key words: high-pressure heater, drainage, regulating valve, blockage, preventive measure