印度尼西亚L电站 #2机组真空查漏措施

蔡攸敏1,张才稳1,万治江2,朱赐英1,郭一兵1   

  1. 1.湖北省电力试验研究院,湖北武汉 430077;2.国电荆门热电厂,湖北荆门 448040
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2011-04-25 发布日期:2011-04-25

Vacuum system leakage detection method for unit No.2 of L Power Plant in Indonesia

CAI Youmin1,ZHANG Caiwen2,WAN Zhijiang2, ZHU Ciying1,GUO Yibing1   

  1. 1.Hubei Electric Power Test and Research Institute, Wuhan 430077, China; 2.Guodian Jingmen Thermal Power Plant, Jingmen 448040, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2011-04-25 Published:2011-04-25

摘要: 介绍了印度尼西亚L电站 #2汽轮机真空系统出现的真空故障,对造成真空故障的原因进行了诊断和分析,运用了灌水法和氦质谱查漏仪对系统漏点进行了查找,找到了低压缸下缸本体特大漏点。采取有效措施后,未再出现凝汽器真空泄漏的问题。

关键词: 真空故障, 氦质谱查漏仪, 查漏, 处理措施

Abstract: The vacuum system fault of steam turbine No.2 of L Power Plant in Indonesia was introduced. The reasons caused the vacuum system fault were diagnosed and analyzed. Using the filling water method and the Helium mass spectrum leakage detector to find the leakage point of the vacuum system, the especially big leakage point was found in lower half casing of low pressure cylinder. The effective measures were adopted, and the condenser vacuum leakage fault does not occur again.