摘要: 对阿萨汉一级水电站并网变功率测振动试验进行研究,从上导+x/+y摆度等方面着手,论述了并网变功率测振动试验的几个测试步骤,重点分析了振动区和相关机组稳定运行的关系,可为其他海外工程提供借鉴和参考。
关键词: 水电站, 变功率测振动, 振动区, 摆度
Abstract: The vibration measurement experiment under synchronization condition with power changing of Asahan First Stage Hydropower Station was studied. Starting from the aspects of the +x/+y swing amplitudes of upper guide bearings and others, the measuring steps of the vibration measurement experiment under synchronization condition with power changing were expounded; and the relationship between the vibration zone and the operation stability of related unit was analyzed emphatically, which can provide some references for other oversea projects.
Key words: hydropower station, vibration measurement with power changing, vibration zone, swing amplitude
陈伟;王志浩;周庆科. 阿萨汉一级水电站并网变功率测振动试验分析[J]. 华电技术, 2011, 33(6): 40-41.
CHEN Wei;WANG Zhihao;ZHOU Qingke. Analysis on vibration measurement experiment under synchronization condition with power changing of Asahan First Stage Hydropower Station[J]. Huadian Technology, 2011, 33(6): 40-41.