摘要: 针对广州某火电厂励磁系统在主、备励切换过程中出现的无功波动大、机组发生失磁事故的问题,对并列可控硅整流、二极管整流的换流过程和备用励磁系统调压装置的机械特性进行了分析,提出了提高励磁系统主、备励切换可靠性的措施,有效地提高了励磁系统主备励切换的可靠性。

关键词: 励磁系统, 主励, 备励, AVR, 可控硅整流, 二极管整流

Abstract: In the switching over operation process between main and stand by excitation systems of a thermal power plant in Guangzhou, the reactive power fluctuated greatly, and the excitationloss accident of the unit was happened. Aiming at the above problems, the current switching process of parallel silicon controlled rectification and diode rectification was analyzed, and the mechanical characteristics of the voltage regulating device of the standby excitation system were analyzed too. The measures to increase the reliability of switching over operation between main and standby excitation systems were put forward, and the reliability of switching over operation between main and standby excitation systems was increased effectively.

Key words: excitation system, main excitation, standby excitation, automatic voltage regulator (AVR), silicon controlled rectification, diode rectification