华电技术 ›› 2011, Vol. 33 ›› Issue (8): 67-69.

• 技术交流 • 上一篇    下一篇

除盐水箱保护涂层的二次脱落分析

黄剑雄,周屹民,俞立凡   

  1. 杭州华电半山发电有限公司,浙江杭州310015
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2011-08-25 发布日期:2011-08-25

Analysis on two peeling off faults of protective coat of demineralized water tank in condensate system

HUANG JIanxiong,ZHOU Yimin,YU Lifan   

  1. Hangzhou Huadian Banshan Power Generation Company Limited, Hangzhou 310015, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2011-08-25 Published:2011-08-25

摘要: 介绍了凝结水系统及出现的异常过程,论述了除盐水箱涂层的作用及要求,列举案例对除盐水箱涂层的二次脱落进行了分析。对出现的异常问题进行了处理,以确保设备的健康运行。

关键词: 除盐水箱, 涂层脱落, 判断分析

Abstract: The condensate system and abnormal process occurred in its operation were introduced. The functions and the requirements of the coat of the demineralized water tank were expounded. By listing practical examples, two peeling off faults of the protective coat of the demineralized water tank was analyzed. The abnormal problems were treated, and the healthy operation of the equipment was ensured.

Key words: demineralized water tank, peeling off fault of the coat, judgment and analysis