600MW机组轴系振动分析及处理

付开慧   

  1. 华电内蒙古能源有限公司包头分公司,内蒙古包头014013
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2012-11-25 发布日期:2012-11-25

Analysis and handling of shafting vibration of 600MW unit

FU Kaihui   

  1. Baotou Power Generation Branch of Huadian Inner Mongolia Energy Company Limited, Baotou 014013, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2012-11-25 Published:2012-11-25

摘要: 华电内蒙古能源有限公司包头发电分公司 #1机组轴系出现了振动偏大问题,对产生振动的原因进行了分析,认为轴系质量不平衡是振动的主要原因。在采取了低压Ⅱ转子两端末级叶轮及低压Ⅱ/发电机转子联轴器动平衡配重措施后,在满负荷稳定运行时,轴系振动均小于70μm,达到了国家标准规定的优良指标。

关键词: 轴系振动, 不平衡量, 晃度, 轴系动平衡, 平衡配重, 临界转速

Abstract: The shafting vibration of the unit No.1 in Baotou Power Generation Branch of Huadian Inner Mongolia Energy Company Limited was larger. The reason of the larger vibration was analyzed; and it was considered that the main reason of the vibration is mass unbalance of the shafting. In last stage blade in the two ends of the lowpressure II rotor and the coupler between the lowpressure II and the generator rotor, the dynamic balance weight measures were adopted. In stable operation of the system with full load, the shafting vibration is less than 70μm, which achieved the good index specified in relevant national standard.

Key words: shafting vibration, amount of unbalance, sway degree, shafting dynamic balance, balance weight, critical rotating speed