华电技术 ›› 2011, Vol. 33 ›› Issue (12): 28-30.
• 研究与开发 • 上一篇 下一篇
徐秀萍,董正帅
收稿日期:
修回日期:
出版日期:
XU Xiuping, DONG Zhengshuai
Received:
Revised:
Published:
摘要: 目前,国内已运行膜法海水淡化系统存在不同程度的问题,尤其是采用超滤作为海水淡化预处理的系统,问题尤甚。国核电力规划设计研究院依托山东某电厂海水超滤膜的现场试验研究,完成了该电厂不同品牌超滤膜的性能验证和对比,获得了相关的试验数据,对超滤膜的选型有一定帮助。
关键词: 膜法海水淡化, 预处理, 超滤膜, 现场试验
Abstract: At present, some problems exist in domestic already running membrane method sea water desalinization systems; especially, in the sea water desalinization systems using ultrafiltration as pretreatment, the problems are more serious. Depending on the field test investigation on sea water ultra filtering membrane of a power plant in Shandong, the State Nuclear Electric Power Planning Design & Research Institute had completed the performance verification and comparison of different brands ultra filtering membranes of the power plant and obtained the related experimental data, which are helpful for selection of ultra filtering membrane.
Key words: sea water desalinization membrane method, pretreatment, ultra filtering membrane, field test
徐秀萍;董正帅. 海水淡化超滤膜选型研究[J]. 华电技术, 2011, 33(12): 28-30.
XU Xiuping;DONG Zhengshuai. Study on selection of ultra filtering membrane for sea water desalinization[J]. Huadian Technology, 2011, 33(12): 28-30.
/ 推荐
导出引用管理器 EndNote|Ris|BibTeX
链接本文: https://www.hdpower.net/CN/
https://www.hdpower.net/CN/Y2011/V33/I12/28
生物膜与浸没式超滤膜组合工艺的应用