华电技术 ›› 2012, Vol. 34 ›› Issue (5): 8-9.

• 专题综述 • 上一篇    下一篇

660MW机组锅炉水冷壁高温腐蚀原因分析及对策

陈可露,饶红建   

  1. 华电新乡发电有限公司,河南新乡453000
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2012-05-25 发布日期:2012-05-25

Analysis on reasons of hightemperature corrosion of water wall in 660MW unit boiler and countermeasures

CHEN Kelu, RAO Hongjian   

  1. Huadian Xinxiang Power Generation Company Limited, Xinxiang 453000, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2012-05-25 Published:2012-05-25

摘要: 某发电公司2台660MW超临界直流锅炉出现水冷壁高温腐蚀现象,指出了导致水冷壁发生高温腐蚀的因素,对侧墙水冷壁烟气温度及成分进行了测试,分析了导致水冷壁发生高温腐蚀的原因并提出了预防措施。

关键词: 水冷壁, 高温腐蚀, 原因分析, 预防措施

Abstract: The hightemperature corrosion occurred in the water walls of two 660MW supercritical oncethrough boilers in a power generation company limited. The factors leading to hightemperature corrosion of the water wall were pointed out. The gas temperature and the chemical components of the gas in side wall of water wall were detected. The reasons of the hightemperature corrosion of water wall were analyzed; and the relevant preventive measures were proposed.