取水泵振动超标的原因分析与处理

  

  1. (中国成达工程有限公司,成都〓610041)
  • 出版日期:2014-11-25 发布日期:2014-12-17

Analysis on reasons of outoflimit vibration of water intake pump

  1. (China Chengda Engineering Company Limited, Chengdu 610041, China)
  • Online:2014-11-25 Published:2014-12-17

摘要: 摘要:介绍了某燃煤电站取水泵在运行中出现的振动超标情况,分析了振动原因,指出了外部管路应力、润滑水压不足、润滑水质差是导致振动超标的主要因素。故障处理后,取水泵振动状况良好,运行正常。

关键词: 关键词:取水泵, 河边取水, 振动, 管路应力, 润滑水, 原因分析, 处理

Abstract: Abstract:In operation of the water intake pump of a coalfired power plant, the vibration of the pump exceeded permitted limit. The reasons of the vibration were analyzed, and it was pointed out that the main reasons causing the overoflimit vibration are the external pipeline stress, the insufficient lubricating water pressure and the poor lubricating water quality. The faults were treated, the vibration of the water intake pump weakened, and the water intake pump operates normally.