摘要:结合某电厂600MW机组屏式过热器夹持管弯头裂纹事件,介绍了304H不锈钢弯头侧弧裂纹分析方法,分析了事件发生原因,并提出了预防措施。

关键词: 关键词:600MW机组, 屏式过热器, 夹持管, 不锈钢弯头, 弯头侧弧裂纹

Abstract:

Abstract:Based on the incident of a power plant’s 600MW unit platen superheater supporting pipe elbow crack,this paper introduced the analysis methodology of 304H stainless steel elbow side crack,analyzed the incident causes,and provided preventive measurements.