华电技术 ›› 2016, Vol. 38 ›› Issue (4): 22-24.

• 技术交流 • 上一篇    下一篇

一起主励磁机转子接地故障的处理与原因分析

  

  1. 广州珠江电厂,广州〓51000
  • 出版日期:2016-04-25 发布日期:2016-07-11

Processing and analysis of the causes of an earth fault of main exciter rotor

  1. Guangzhou Zhujiang Power Plant,Guangzhou 51000,China
  • Online:2016-04-25 Published:2016-07-11

摘要:

摘要:介绍了外加电源注入式转子接地装置RCS-985RE的保护原理以及转子接地产生的相关危害,结合一套三机他励励磁系统的主励磁机转子一点接地故障实例,提出了故障处理相应步骤,并分析了故障发生的原因。同时指出,转子接地保护装置在特定运行方式下不能检测有关系统故障,并给出了合理的辅助测量判断手段。

关键词:

Abstract:

Abstract:This paper introduced protection principle of injection type of rotor earth fault protection equipment generated by additional power and hazard of rotor earthing.Based on an earth fault of main exciter rotor of a set of separate excitation system,this paper proposed a process of fault handling and analyzed the cause of this fault.At the same time pointed out that the system failure cannot be detected if rotor earth fault protection equipment is under specific operation mode.A reasonable judgment means of assistant measuring is provided.

Key words: