摘要:

摘要:针对华电潍坊发电有限公司#4机组4B轴加风机轴系振动较大事宜,通过分析振动数据,推断轴加风机轴系存在转子质量不平衡现象。通过动平衡计算,在风机叶轮顶部加装平衡块,成功解决了轴加风机轴系振动较大现象,为同类型机组类似现象提供了参考依据。

关键词:

Abstract:

Abstract:Based on the incident of serious vibration of Huadian Weifang Power Plant’s unit No.4 and 4B shaft, by analyzing vibration data, it was concluded that the sealing heater fan shaft is rotating unbalance. After counterbalance was added on fan impeller top according to balance calculation, the problem of serious vibration was solved. Which could be refer by similar unit.