直吹式制粉系统粉管堵塞试验测试及处理

  

  1. 中国大唐集团科学技术研究院有限公司华中分公司,郑州〓450000
  • 出版日期:2017-01-25

Direct firing pulverizing system coal powder pipe blockage test and treatment

  1. China Datang Corporation Science and Technology Research Institute Central China Branch, Zhengzhou 450000, China
  • Published:2017-01-25

摘要:

某电厂 #4磨煤机一次风管易出现堵塞特征,多次检查、调整,仍无法解决。对该制粉系统的粉管风速、煤粉细度、粉管煤粉质量分数进行测试,确认堵塞的原因是煤粉局部富集。对磨煤机进行分离器挡板检查测量调整后,一次风管未再出现堵塞迹象,问题得到解决。

关键词:

Abstract:

Blockage frequently happened on a power plant’s No.4 pulverizer. After times of examination and adjustment, this problem remained. By tests of powder pipe air speed, coal powder fineness and powder concentration, the cause of blockage was determined as partial powder aggregation. After adjusting pulverizer separator damper, blockage was eliminated.