摘要:

以湛江调顺电厂2×600MW机组为例,介绍了循环水泵的常见故障,分析了故障原因并给出了改造方案。改造方案实施后,提高了循环水泵的安全、可靠性,取得了良好的经济效益。

关键词:

Abstract:

Based on Zhanjiang Tiaoshun Power Plant 2×600MW, common failure of circulating water pump was introduced. Failure cause was analyzed. Treatment was provided accordingly. After treatment, safety, reliability of circulating water pump was increased. Economic benefits was obtained.