Huadian Technology ›› 2010, Vol. 32 ›› Issue (1): 41-42.

• 技术交流 • Previous Articles     Next Articles

Frequency conversion reformation of condensate pump and application in 600MW unit

YANG Jianping, ZHAO Zuoqi   

  1. Huadian Baotou Power Generation Corporation Limited, Baotou 014013, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2010-01-25 Published:2010-01-25

Abstract: The problems existed in condensate system of 2×600MW coalfired units of Huadian Baotou Power Generation Corporation Limited were analyzed. The problems, such as pipe vibration of condensate system, were solved, and obvious energysaving effect was obtained. The result can be used as reference for similar units in frequency conversion reformation.

Key words: condensate pumps, frequency conversion, water level in deaerator