Huadian Technology ›› 2010, Vol. 32 ›› Issue (1): 41-42.
• 技术交流 • Previous Articles Next Articles
YANG Jianping, ZHAO Zuoqi
Received:
Revised:
Published:
Abstract: The problems existed in condensate system of 2×600MW coalfired units of Huadian Baotou Power Generation Corporation Limited were analyzed. The problems, such as pipe vibration of condensate system, were solved, and obvious energysaving effect was obtained. The result can be used as reference for similar units in frequency conversion reformation.
Key words: condensate pumps, frequency conversion, water level in deaerator
YANG Jianping;ZHAO Zuoqi. Frequency conversion reformation of condensate pump and application in 600MW unit[J]. Huadian Technology, 2010, 32(1): 41-42.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2010/V32/I1/41
Discussion on energysaving scheme for cooperative desulfurization with liquid column injection and atomization spray
Optimization of deep frequency conversion transformation for condensate pump in 1000MW secondary reheat unit