Huadian Technology ›› 2008, Vol. 30 ›› Issue (7): 52-53.
• 一线动态 • Previous Articles Next Articles
HUANG Zi-bo
Received:
Revised:
Published:
Abstract: Based on the phenomenon of abnormal temperature difference of the effluent coolant of 600MW generator’s stator wingding bar in a power plant during operation, this paper provided a comprehensive analysis for its causes, outlined the solution process, and proposed the treatment countermeasures for abnormal temperature difference of effluent coolant.
Key words: generator stator winding bar, abnormal temperature difference of effluent coolant, reason analysis, treatment countermeasure
HUANG Zi-bo. Analysis and Countermeasures on Abnormal Temperature Difference of a 600MW Turbo-generator’s Stator Winding Bar effluent Coolant[J]. Huadian Technology, 2008, 30(7): 52-53.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2008/V30/I7/52