Huadian Technology ›› 2012, Vol. 34 ›› Issue (2): 13-15.
• 专题综述 • Previous Articles Next Articles
WENG Jinyu
Received:
Revised:
Online:
Published:
Abstract:
Due to that there are many factors influencing on the tube cracking fault, and it can not judge the positions on low header outlet and upper header
outlet corresponding with the spiraled tubes intuitively, it is difficult to find the reason of tube cracking of spiral water wall in a 600MW unit. Based
on the metallographic analysis, the chemical analysis and the mechanical test of the cracked tube, it was found that the main reason of the water wall tube
cracking is overtemperature, and the preventive measures were given, which provides certain reference for tube cracking analysis.
Key words: spiral type water wall, tube cracking, overtemperature, hurt, reason analysis, preventive measures
WENG Jinyu. Analysis and prevention of tube crack of water wall in 600MW supercritical unit[J]. Huadian Technology, 2012, 34(2): 13-15.