Huadian Technology ›› 2013, Vol. 35 ›› Issue (3): 43-44.
• 技术交流 • Previous Articles Next Articles
FAN Wenbin
Received:
Revised:
Published:
Abstract: The structure of HP type mediumspeed mill was introduced. The defects of HP type mediumspeed mill in operation, such as the serious wear of the scraper, the coal contained in discharged gravels, the decreased oil viscosity in lubricatingoil station, the jamming of slag discharging pneumatic gate, the air leakage in primary hot air regulating gate, the larger dust concentration during slag discharging, the falling off fault of the wearresisting scaleboard and others, were analyzed. The feasible preventive measures were formulated; the defects of the equipment were eradicated completely, and the operation reliability of the mill was enhanced.
Key words: medium-speed mill, scraper wear, oil viscosity, jamming, air leakage
FAN Wenbin. Analysis on fault of HP type mediumspeed mill and countermeasures[J]. Huadian Technology, 2013, 35(3): 43-44.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2013/V35/I3/43
Optimization of air preheater leakage control system in 670MW unit