Abstract:There were problems in traditional auxiliary bus protection of power plant. Aiming at these problems, it was proposed that to adopt passive wireless temperature measuring technology to realize fast auxiliary bus protection. Under the framework of traditional relay protection, the nonelectrical signals protection is used to eliminate the protection dead zone of electrical signals protection for faults of 6kV auxiliary bus and to quikly switch the fault of 6kV auxiliary bus. Then the primary equipments, such as the high voltage auxiliary transformer and the startup and standby transformer, can be protected.
Key words: Keywords:auxiliary bus, passive wireless temperature measuring technology, temperature collector, fast protection
PAN Qiming. Fast auxiliary bus ptotection based on passive wireless temperature measurement technology[J]. Huadian Technology, 2015, 37(8): 59-60.