Cracking cause analysis and treatment of cold reheated steam Tpiece of a 450MW gas turbine

  

  1. Huadian Electric Power Research Institute Company Limited, Ji’nan 250014, China
  • Online:2019-02-25 Published:2019-03-13

Abstract: