华电技术 ›› 2008, Vol. 30 ›› Issue (10): 61-62.

• 一线动态 • 上一篇    下一篇

氢冷机组氢气纯度低的分析及改进措施

盛虎   

  1. 华电章丘发电有限公司 地址:山东省章丘市 250216
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2008-10-25 发布日期:2008-10-25

Research of hydrogen purity decrease in hydrogen cooled unit

SHENG Hu   

  1. Huadian Zhangqiu Power Generation Corporation Limited, Zhangqiu 250216, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2008-10-25 Published:2008-10-25

摘要: 针对华电章丘发电有限公司#3机组氢气纯度下降较快并致使机内氢气经常需要提纯的问题进行了分析,采取了相应的措施,利用运行和停机机会对密封油系统进行了调整。最终使氢气纯度下降问题得到了解决,保证了机组的安全稳定运行。

关键词: 氢冷机组, 氢气纯度, 提纯, 密封油系统, 调整

Abstract: The hydrogen purity of unit №3 in Huadian Zhangqiu Power Generation Corporation Limited was decreasing faster, and this caused that the hydrogen inside generator must be purified frequently. The problems mentioned above were analyzed, some relevant measures were adopted, and the sealing oil system was adjusted using running and shut-down opportunity. Then the problem of hydrogen purity decrease was resolved finally, and unit safety, stable operation was achieved.

Key words: hydrogen cooled unit, hydrogen purity, purification, sealing oil system, adjustment