华电技术 ›› 2008, Vol. 30 ›› Issue (11): 72-75.
• 控制技术 • 上一篇 下一篇
何同祥,刘会娟,刘会赏
收稿日期:
修回日期:
出版日期:
HE Tongxiang,LIU Huijuan, LIU Huishang
Received:
Revised:
Published:
摘要: 介绍了某电厂#4机组子控制系统的工作原理,对子控制系统存在的问题进行了分析,提出了合理可行的优化措施。经对控制方案和参数优化以后,子控制系统具有良好的调节品质,能满足正常运行、负荷变动及RB试验要求。
关键词: 送风控制, 引风控制, 过热汽温, RB试验, 系统优化
Abstract: The working principle of control subsystems of unit No.4 in a certain power plant were introduced, the problems existed in the subsystems were analyzed, and some reasonable, feasible optimizing measures were proposed. After perfecting of control plan and optimization of control parameters, the better adjustment quality of control subsystems was achieved, and the requests of the normal operation, the load variation and the RB test can be satisfied.
Key words: forced draft control, induce draft control, superheated steam temperature, RB test, system optimization
何同祥;刘会娟;刘会赏. 300MW机组MCS子控制系统优化[J]. 华电技术, 2008, 30(11): 72-75.
HE Tongxiang;LIU Huijuan;LIU Huishang. Optimization of MCS subcontrol system for 300MW units[J]. Huadian Technology, 2008, 30(11): 72-75.
/ 推荐
导出引用管理器 EndNote|Ris|BibTeX
链接本文: https://www.hdpower.net/CN/
https://www.hdpower.net/CN/Y2008/V30/I11/72