华电技术 ›› 2010, Vol. 32 ›› Issue (2): 4-6.

• 专题综述 • 上一篇    下一篇

协调优化控制系统在480t/h循环流化床锅炉的应用

祝学存   

  1. 华电乌达热电有限公司,内蒙古乌海016040
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2010-02-25

Application of coordinated optimal control system in 480t/h circulating fluidized bed boiler

ZHU Xuecun   

  1. Huadian Wuda Thermo Power Generation Corporation Limited, Wuhai 016040, China
  • Received:1900-01-01 Revised:1900-01-01 Published:2010-02-25

摘要: 内蒙古华电乌达热电有限公司机组因循环流化床锅炉燃烧的复杂性和特殊性,使得锅炉的燃烧系统自动控制难以正常投入,通过使用“循环流化床锅炉燃烧过程优化控制系统”,实现了480t/h级CFB锅炉燃烧自动控制,在此基础上实现了机组协调控制。

关键词: 循环流化床, 无辨识自适应控制, 燃烧自动调节, 机组协调控制

Abstract: The CFB boiler combustion automaton control of Inner Mongolia Huadian Wuda Thermo Power Generation Corporation Limited was difficult to put in operation normally due to the complexity and the particularity of CFB boiler combustion. By using the control software CFB boiler combustion process optimal control system, the combustion automatic control for 480t/h level CFB boiler was realized. Based on this, the unit coordinated control was realized.

Key words: circulating fluidized bed (CFB), adaptive control without identification, automatic adjustment of combustion, unit coordinated control