华电技术 ›› 2010, Vol. 32 ›› Issue (5): 24-25.

• 技术交流 • 上一篇    下一篇

制氢系统突然停车的原因及处理

蒋勇   

  1. 四川广安发电有限责任公司,四川广安638000
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2010-05-25

Reason of accidental shutdown of the hydrogen generation system and treatment

JIANG Yong   

  1. Sichuan Guangan Power Generation Corporation Limited, Guangan 638000, China
  • Received:1900-01-01 Revised:1900-01-01 Published:2010-05-25

摘要: 以四川广安发电有限责任公司2×600MW机组制氢设备为例,分析了发电机制氢系统在运行当中突然停车的原因,给出了相应的处理办法。

关键词: 制氢设备, 电解槽, 联跳, 故障, 报警

Abstract: Taking the hydrogen generation equipment of 2×600MW unit of Sichuan Guangan Power Generation Corporation Limited as example, the reasons of the sudden stoppage of the hydrogen generation system during operation were analyzed, and relevant treatment methods were given. 

Key words: hydrogen generation equipment, electrolytic tank, intertrip, fault, alarm