华电技术 ›› 2010, Vol. 32 ›› Issue (8): 15-17.

• 研究与开发 • 上一篇    下一篇

600MW超临界机组联合引风机选型分析

闫桂林   

  1. 广东省粤电集团茂名热电厂,广东茂名525000
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2010-08-25

Analysis on type selection of combined induced draft fan for 600MW supercritical unit

YAN Guilin   

  1. Maoming Cogeneration Plant of Guangdong Yudean Group, Maoming 525000, China
  • Received:1900-01-01 Revised:1900-01-01 Published:2010-08-25

摘要:

从风机运行经济性、调节效率、设备费用、维护费用和可靠性的角度出发,对动叶调节轴流风机和静叶调节轴流风机进行了对比,通过对联合引风机的选型分析,得到了适合于茂名热电厂实际情况的风机选型结果。

关键词: 600MW超临界机组, 联合引风机, 选型

Abstract: From the perspective of the economical operation, the adjustment efficiency, the equipment cost, the maintenance cost and the reliability of the fan, the movingvane adjustable axial flow fan had been compared with the staticvane adjustable axial flow fan. According to the analysis of type selection of combined induced draft fan, the type selection result of the fan suitable to the practical situation of the Maoming Cogeneration Plant was obtained.

Key words: 600MW supercritical unit, combined induced draft fan, type selection