摘要: 分析了简化脱硫系统配置,优化主要设备选型,增加防腐、防磨措施的可行性,论述了取消烟气旁路后保证脱硫装置可靠性的措施,供烟气脱硫系统设备配置与选型时参考。
关键词: 湿法脱硫, 烟气换热器, 无旁路, 烟塔合一, 设备配置, 选型
Abstract: The feasibility of simplifing the desulphurization system configuration, optimizing the main equipments selection and adding anticorrosion and antiabrasion measures were analyzed. The measures for ensuring the reliability of desulphurization equipments after eliminating the flue gas bypass were expounded, which can be used as reference for FGD system in equipment configuration and selection.
Key words: wet desulphurization, gas-gas heater (GGH), without bypass, cooling water in place of chimney combining tower, equipment configuration, type selection