摘要: 介绍了某电厂微油点火系统改造后在锅炉冷、热态启动、低负荷稳燃运行的应用情况,通过改造并建立锅炉优化燃烧及混煤掺烧管理体系,取得了良好的经济效益,提升了电厂的盈利能力。

关键词: 超临界, 微油点火, 优化燃烧, 混煤掺烧, 管理体系

Abstract: The tinyoil ignition system reformation had been accomplished in a power plant. The application situations of the tinyoil ignition system in the cold start, the hot start and lowload stable combustion operation of the boiler were introduced. Based on the reformation and the establishment of the management system for the boiler optimized combustion and blended coal burning, the favorable economic benefit was obtained.

Key words: 600MW unit, supercritical unit, tiny-oil ignition, optimized combustion, blended coal burning, management system