摘要:

姚孟发电有限责任公司 #1锅炉甲侧吸风机运行中出现失速现象,通过数据和理论分析认为, #1锅炉甲侧吸风机失速原因为空气预热器低温腐蚀积灰引起,采取了有效

措施后,失速现象消失。

关键词: 吸风机, 失速, 低温腐蚀, 积灰, 应对措施

Abstract:

In operation of side A induced draft fan of boiler No.1 in Yaomeng Power Company Limited, the stall phenomenon occurred. According to the operation

data and theory analysis, it was considered that the stall reason of the said induced draft fan is low temperature corrosion caused by ash deposition of the

preheater. After effective measures were adopted, the stall phenomenon was eliminated.

Key words: induced draft fan, stall, low temperature corrosion, ash deposition, responsive measure