凝结水精处理系统无凝结水补水箱时的运行方式分析

林福海   

  1. (江西省电力科学研究院,江西南昌 330096)
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2013-03-25 发布日期:2013-03-25

Analysis on operation of condensate polishing system without condensate makeup water tank

LIN Fuhai   

  1. (Jiangxi Electric Power Research Institute, Nanchang 330096, China)
  • Received:1900-01-01 Revised:1900-01-01 Online:2013-03-25 Published:2013-03-25

摘要: 以某电厂凝结水精处理系统无凝结水补水箱的情况为例,对机组启动和正常运行2个阶段精处理系统的运行情况进行了分析,给出了具体的处理措施,供采用类似运行方式时参考。

关键词: 火电厂, 凝汽器, 凝结水补水箱, 凝结水精处理, 运行方式

Abstract: Taking the condensate polishing system without condensate makeup water tank of a power plant as example, the operational aspects of the condensate polishing system in processes of startup and normal operation of the unit were analyzed. Some concrete treatment measures were given, which can be used as reference for other units operating in similar mode.

Key words: thermal power plant, steam condenser, condensate make-up water tank, condensate polishing, operation mode