摘要: 摘要:以某电厂2×700MW机组为例,介绍了除氧器水位控制原理及控制方式,结合故障现象进行了故障原因分析,给出了具体处理措施,处理后取得理想效果。

关键词: 关键词:汽轮机, 除氧器, 水位控制, 控制方式

Abstract: Abstract:Taking the 2×700MW unit of a power plant as example, the principle of the deaerator water level control system and the control mode were introduced. Combining with the fault phenomenon, the reasons of the fault were analyzed, and concrete treatment measures were given. The ideal result was obtained.