华电技术 ›› 2016, Vol. 38 ›› Issue (5): 64-67.

• 节能与环保 • 上一篇    下一篇

超低排放对烟气排放连续监测系统设计的影响

  

  1. 山东电力工程咨询院有限公司,济南〓250013
  • 出版日期:2016-05-25 发布日期:2016-07-15

Effect of ultralow emission on gas flow continuous detecting system design

  1. Shandong Electric Power Engineering Consulting Institute Company Limited, Jinan 250013, China
  • Online:2016-05-25 Published:2016-07-15

摘要:

摘要:近年来,国家对燃煤电厂污染物排放的监管越来越严格,电厂为达到超低排放而采用的技术会引起烟气排放连续监测系统(CEMS)设计方案发生变化。介绍了CEMS工作原理,结合双塔串联、双塔双循环、双塔并联等不同超低排放技术,分析了其对CEMS设计方案的影响,并对比了不同超低排放技术对CEMS仪表选型的影响。

关键词:

Abstract:

Abstract:Recent years, government’s regulation of power plant pollution emission became more and more strict. Technology applied to achieve ultralow emission will affect the design continuous emission monitoring system (CEMS). The operation principle of CEMS was introduced. Combined with twintower cascade, twintower duocycle and twintower multiple and other ultralow emission technology, the affection of different ultralow emission technologies on the design of CEMS was analyzed.

Key words: