华电技术 ›› 2017, Vol. 39 ›› Issue (5): 44-49.

• 技术交流 • 上一篇    下一篇

调节保安系统故障引发的误停机事故分析

  

  1. 广州环投南沙环保能源有限公司,广州〓511400
  • 出版日期:2017-05-25

Mistaken stop by governing and protecting system analysis

  1. GZEPI Nansha Green Energy Company Limited, Guangzhou 511400, China
  • Published:2017-05-25

摘要:

对广州某热电厂100MW热电联产机组调节保安系统进行了详细介绍,在此基础上,对因调节保安系统关键部件缺陷引发的2次误停机事故进行了分析,并对2次事故后的检查和处理情况进行总结,提出了整改和防范措施。

关键词:

Abstract:

The governing and protecting system of a power plant 100MW unit was detailed introduced. Two mistaken stop incidents caused by defects of governing and protecting system were analyzed. Inspection and treatment of these two incidents was summarized. An improvement and prevention measures was indicated.

Key words: