华电技术 ›› 2017, Vol. 39 ›› Issue (6): 59-60.

• 技术交流 • 上一篇    下一篇

600MW超临界W火焰锅炉水压试验系统优化

  

  1. 贵州华电桐梓发电有限公司,贵州遵义〓563200
  • 出版日期:2017-06-25 发布日期:2017-07-10

600MW supercritical W flame boiler water pressure test system improvement

  1. Guizhou Huadian Tongzi Power Plant Company Limited,Zunyi 563200, China
  • Online:2017-06-25 Published:2017-07-10

摘要:

创新性的采用空气预热器高压冲洗水泵作为锅炉一次系统水压试验升压泵,并对泵的水源、管路系统、电控装置进行优化,实现了对锅炉一次系统原水压试验系统的优化,规避了耗时长、操作复杂、试验成本高、易延误检修工期等问题。

关键词:

Abstract:

The practice that use air preheater high pressure wash pump as boiler primary system hydraulic test boost pump was introduced. The water source, pipeline and control system was improved. The improvement of existed boiler primary system hydraulic test system was realized. The problems of long time consumption, complicated operation, high tests cost and maintenance delay was avoided.

Key words: