330MW亚临界锅炉高温过热器爆管原因浅析

  

  1. 1.福建电力职业技术学院,福建泉州〓362000; 2.福建华电漳平火电有限公司,福建龙岩〓364400
  • 出版日期:2018-08-25 发布日期:2018-09-20

Cause analysis on tube bursting since hightemperature overheating in a 300MW subcritical boiler

  1. 1.Fujian Electric Vocational and Technical College,Quanzhou 362000,China; 2.Fujian Huadian Zhangping Thermal Power Generation Company Limited,Longyan 364400,China
  • Online:2018-08-25 Published:2018-09-20

摘要:

针对某电厂330MW亚临界锅炉高温过热器爆管事故,借助宏观形貌分析、化学成分分析、金相组织分析和力学性能分析,判断该爆管事故是因长期超温和短期过热(异物堵管)共同作用所致。

关键词:

Abstract:

Based on the macromorphological analysis, chemical composition analysis, metallographic strcture analysis and mechanical property analysis, a tube bursting since hightemperature overheating in a 300MW subcritical boiler of a power plant is analyzed. It turns out that the tube bursting is due to both longterm over temperature and shortterm overheating (tube blocked by foreign matter).