华电技术 ›› 2012, Vol. 34 ›› Issue (12): 58-60.
• 技术交流 • 上一篇 下一篇
邓英
收稿日期:
修回日期:
出版日期:
DENG Ying
Received:
Revised:
Published:
摘要: 对四川广安发电有限责任公司一期工程一级除盐设备酸碱耗高的原因进行了分析,提出了具体的调整措施,制订出了最佳的树脂再生工艺。调整后除盐系统阴、阳树脂再生酸碱耗明显下降,提高了除盐系统树脂再生的经济性。
关键词: 一级除盐, 酸碱耗, 阴, 阳树脂, 原因分析, 措施
Abstract: The reasons of higher acid and alkali consumptions of first stage desalinization equipment in Sichuan Guang’an Power Generation Company Limited project phase I were analyzed. The concrete regulating measures were proposed, and the optimal resin regeneration process was formulated. After the regulation, the acid and alkali consumption of the desalinization system for anion exchange resin and cation exchange resin regeneration decreased obviously, and the economic efficiency of the resin regeneration of desalinization system was increased.
Key words: first stage desalinization, acid and alkali consumption, anion exchange resin and cation exchange resin, reason analysis, measure
邓英. 一级除盐设备酸碱耗高的原因分析及处理[J]. 华电技术, 2012, 34(12): 58-60.
DENG Ying. Reason analysis and treatment of high acid and alkali consumptions of first stage desalinization equipment[J]. Huadian Technology, 2012, 34(12): 58-60.