摘要: 关键词:长期停(备)用锅炉;正压热风吹干法;湿法保养;干法保养

Abstract: Abstract:The well maintenance of the inside of boiler, which was stopped as standby for long term, is the basic premise for ensuring safe and economic operation of the boiler. The corrosion is important factor to shorten the service life of the boiler stopped as standby for long term. Taking the boiler optimized maintenance method of Fujian Huadian Shaowu Power Generation Company Limited as example, the reasons and the damages of boiler corrosion were analyzed, and the advantages and the disadvantages of various maintenance methods were analyzed. The analysis results are useful for safe and economic maintenance of the boiler.

Key words: Keywords:boiler stopped as standby for long term, positive pressure hot air blow drying method, wet maintenance method, dry maintenance method