Huadian Technology ›› 2008, Vol. 30 ›› Issue (2): 54-58.
• 一线动态 • Previous Articles Next Articles
WANG Xin-ge,KONG Lin, CHEN Cai-liang
Received:
Revised:
Published:
Abstract: With the increment of desulphurization projects, how to ensure the stable operating of large capacity desulphurization equipments is getting more attention. Familiar malfunction of the desulphurization booster fan was introduced in view of 2×600 MW units(project iii ) and 2×1000 MW units(project iv) in the Zouxian Power Plant during commissioning. The malfunction problems were analyzed from the design, the installment, the operating and the overhaul. The corresponding processing measures were taken, which avoided the accident.
Key words: large capacity units, booster fan, familiar malfunctions, analysis and disposal
WANG Xin-ge;KONG Lin;CHEN Cai-liang. Familiar malfunction and disposal of booster fan in large capacity units [J]. Huadian Technology, 2008, 30(2): 54-58.